LC ENGINEERING SERVICES SDN BHD  is a Company  based in Kuala Lumpur, Malaysia, dedicated to the business of Condition Monitoring using the technique of INFRARED THERMOGRAPHY since 1989. To complement the service, other related techniques like Ultrasound, Partial Discharge,Vibration Monitoring, Oil Analysis, etc, have been added.

Existing Clients are currently located in South East Asian Countries like Malaysia, Singapore, Thailand, Indonesia,Philippines, to China, Australia and other surrounding areas. The service covers a wide range of industries like Petrochemical, Oil & Gas, Automotive, Pharmaceuticals, Steelworks, Agricultural, Pulp & Paper, Power Generation, Electronics, etc.

Among our Customers, are International names like Ansell, Baxter, BP Amoco, Cabot, Cargill, Esso, Hewlett Packard, Intel, Kimberley Clark, Motorola, Philip Morris, Procter Gamble, Seagate, Shell, Texas Instruments, etc.

A team of qualified Professionals and technically competent staff provide the services required for implementation of the various disciplines.

Our experience in Infrared Thermography covers a very wide range of applications not only in Electrical installations, but also other important areas like Furnaces, Reactors, Cryogenic equipment, pipelines, chimney stacks, bearings, steam lines, etc.

A combination of both Infrared Thermography and Partial Discharge together with Ultrasound testing is often used for condition based predictive maintenance of electrical equipment. The Partial Discharge/Ultrasound testing detects faults resulting from ionization & corona which are developing in enclosed switchgear long before any form of heat is detectable through the use of Infrared Thermography.

Partial Discharge Testing, complemented by Ultrasound inspection for High Voltage Insulation Testing has been very widely used successfully not only in 132/275kV outdoor Substations, but also extensively in indoor HV panels. Corona detection has been made much simpler with the availability of high quality Instruments.

In the field of Ultrasound inspection, this covers a very wide field which includes detection of arcing & corona discharge before flash-over, pressure & vacuum leaks, liquid leaks, pump cavitation, valve leakages, steam trap defects, etc.

Vibration Monitoring is used to determine the operating condition of rotating equipment to identify potential problems before they fail. Problems can be due to unbalance, misalignment, mechanical looseness, defective bearings, worn gears, etc.

Oil analysis is an effective method for early detection of faults. For transformer oil, dissolved gas analysis allows determination of the various types of faults like insulation breakdown, internal arcing & sparking, etc. Metals in oil analysis complements dissolved gas analysis to enable the type of fault to be identified.

Equipment wear problems can be identified through oil debris analysis by the detection of type, size and shape of metal particles within the oil sample.


OUR PRODUCTS

Infrared Thermography  |  IR Windows Partial Discharge & Ultrasound  |  DGA